Product Details
Monitoring capabilities
| Parameter | Displayed Information | Measurement & Setup |
|---|---|---|
| ECG / Heart Rate | ECG waveform and heart rate in bpm. | A 5-lead ECG cable and disposable electrodes acquire the electrical signal. Reliable electrode contact is required. |
| SpO₂ / Pulse Rate | Oxygen saturation in % and pulse rate in bpm. | The SpO₂ probe provides an optical measurement. Position the probe at a suitable site and check signal quality. |
| NIBP | Systolic, diastolic and mean blood pressure in mmHg. | Oscillometric cuff measurement, started manually or repeated automatically. Cuff size and fit must suit the animal. |
| RESP | Respiratory waveform and rate in breaths/min. | Impedance respiration is measured through the ECG electrode setup. A usable electrode signal is required for the respiratory trace. |
| TEMP | Temperature readings from the connected probe. | Use the temperature probe at a measurement site appropriate for the probe type and veterinary procedure. |
Animal fit and accessory selection
The adjustable blood pressure cuff and repositionable probes help veterinary teams adapt the monitoring setup to different animals. Adjust the cuff for a proper fit and position each probe at a suitable measurement site, then check contact and signal quality before monitoring.
Built-in thermal printing & record review
- Printing: Press PRINT to produce a real-time printout of supported waveforms and parameter values.
- Data review: Freeze waveforms for closer inspection, or review available trends and previous records.
- Paper supply: Uses compatible thermal recording paper. Check that paper is loaded before printing.
Color display & physical controls
- Display & navigation: View waveforms and numerical readings together. Turn the rotary control to navigate or adjust values; press to select.
- NIBP control: Press NIBP to start or stop a cuff blood pressure measurement.
-
Menu settings: Access on-screen menus to adjust system and monitoring parameters.
Patient Alarms & Equipment Prompts
- Audible & visual alerts: Sound and light signals draw attention to readings outside configured alarm limits.
- Adjustable limits: Set supported parameter alarm limits for the animal and monitoring task.
- Equipment prompts: On-screen messages flag disconnected leads or sensors and low battery conditions.
Connections, Power & Handling
- Accessory connections: Dedicated sockets connect the ECG cable, SpO₂ and temperature probes, and NIBP cuff assembly.
- AC & battery power: Operates on AC power or its rechargeable internal battery. Check battery charge before disconnecting AC power.
- Carrying handle: The integrated handle helps you reposition the monitor. Place it securely with ventilation openings clear.
Technical Specs
| Specification | Details |
|---|---|
| Monitoring parameters | ECG/heart rate, SpO₂/pulse rate, non-invasive blood pressure, respiration and temperature |
| ECG lead configuration | 5-lead ECG cable |
| NIBP measurement | Oscillometric measurement of systolic, diastolic and mean blood pressure |
| NIBP modes | Manual and automatic interval measurements |
| Respiration measurement | Impedance measurement through ECG electrodes |
| Display | 12.1-inch color TFT; 1024 × 768 pixels |
| Controls | Front-panel buttons and a press-to-select rotary knob |
| Printer | Built-in thermal printer, included in the standard configuration |
| Alarms | Audible and visual alerts with adjustable parameter alarm limits |
| Data review | Waveform freeze, trend display and record review |
| Power supply | AC mains and an internal rechargeable lithium battery |
| AC input | 100–250 V AC, 50/60 Hz |
| Dimensions (H × W × D) | 300 × 310 × 160 mm |
| Operating conditions | Temperature: 0–40 °C; relative humidity: ≤85% |
| Storage conditions | Temperature: −20–60 °C; relative humidity: ≤93% |
| Warranty | 1 year |
What’s in the Box
| Included Item | Quantity |
|---|---|
| Veterinary monitor with built-in thermal printer | 1 |
| 5-lead ECG cable | 1 set |
| NIBP cuff | 1 |
| SpO₂ probe | 1 |
| Temperature probe | 1 |
| Disposable ECG electrodes | 1 pack |
| Power cord | Included |
Use Cases
Procedure Monitoring
View ECG/heart rate, SpO₂, non-invasive blood pressure, respiration and temperature during veterinary procedures. Adjustable alarms help the attending team notice readings outside the configured limits.
Supervised Recovery
Continue observing vital signs during supervised recovery after a procedure. Trend and record review help the veterinary team compare current readings with earlier measurements.
Clinical Assessment
Bring key vital-sign readings together during veterinary examinations. Review measurements alongside the physical examination, and print supported waveforms and parameter values when a paper record is needed.
Setup & Care
Inspect and prepare
Check the monitor, cables and probes for damage. Set the unit on a stable surface, connect the appropriate power cord and confirm battery charge.
Connect and configure
Trained staff fit the patient accessories, select the required settings, and verify usable signals and alarm operation before beginning the session.
Finish and clean
Complete the required record, then power off and disconnect the monitor before cleaning. Follow the cleaning instructions for each accessory; keep liquid out of the unit and connectors.
FAQ
Only use accessories confirmed as compatible with this monitor and suitable for the measurement site. Connector shape alone does not establish electrical or functional compatibility; check the accessory specification before substituting it.
Compare the intended measurement-site circumference with the cuff’s specified fitting range, then follow your veterinary protocol for placement. The standard package is not an assortment of cuff sizes.
No. This configuration uses a five-lead ECG cable for monitoring. It is not presented as a diagnostic 12-lead ECG system; choose the appropriate diagnostic equipment when a 12-lead examination is required.
No. NIBP produces cuff-based measurements. Automatic mode repeats measurement cycles; it does not turn the cuff into a continuous beat-to-beat pressure waveform source.
Plan for replacement disposable ECG electrodes and compatible thermal recording paper. For paper reorders, verify the paper type, width and roll size required by the installed recorder.
Assess the animal directly, then check accessory connections, fit, signal contact and any technical messages. Do not interpret a missing trace as a normal result. If the issue remains, follow the equipment troubleshooting instructions or obtain qualified technical support.